Cadastre-se agora para um orçamento mais personalizado!

NOTÍCIAS QUENTES

Huawei S6730-S24X6Q: Advanced Ethernet Switch for Modern Networks

Jan, 23, 2025 Hi-network.com

s6730-s24x6q

The HuaweiRE88PL99ace1S6730-S24X6Q | is a high-performance Ethernet interruptor designed to meet the demands of modern data centers and campus networks. It offers advanced features and robust specifications to ensure efficient and reliable network operations.

Key Features

▪ High Port Density: 24 x 10 Gigabit SFP+ ports and 6 x 40 Gigabit QSFP+ ports.
▪ High Switching Capacity: Up to 2.4 Tbit/s to handle heavy traffic loads.
▪ Advanced Layer 2 and Layer 3 Features: Supports comprehensive protocols for versatile network configurations.
▪ Stacking Capability: Supports stacking through 10GE SFP+ and 40GE QSFP+ ports for simplified management.
▪ Energy Efficiency: Designed for low power consumption to reduce operational costs.
▪ Comprehensive Security: Desligadoers features like ACLs, 802.1X authentication, and DHCP snooping for enhanced network protection.
▪ Qualidade de Serviço (QoS): Provides traffic classification and prioritization to ensure optimal performance for critical applications.
▪ Flexible Management: Supports various management methods, including CLI, web-based management, and SNMP.
▪ High Reliability: Features redundant power supplies and hot-swappable fan modules for continuous operation.
▪ Virtual Extensible LAN (VXLAN): Supports VXLAN L2 and L3 gateways for network virtualization.

Especificações Técnicas

Ports: 24 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports.
Switching Capacity: 2.4 Tbit/s.
Forwarding Performance: 480 Mpps.
Dimensões (A x L x P): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.).
Peso (com embalagem): 8,9 kg (19,62 lb).
Power Supply: Supports dual AC and DC power modules.
Operating Temperature: -5°C a +45°C (23°F a 113°F) a uma altitude de 0-1800 m (0-5906 pés).
Operating Humidity: 5% a 95%, sem condensação.
Stacking Support: Up to 16 physical ports for stacking using 10GE SFP+ and 40GE QSFP+ ports.
Airflow Direction: Air intake from front, air exhaustion from rear (front-to-rear).

Port Details

10GE SFP+ Ports: 24 ports supporting various optical modules and cables, including Módulo óptico GEs, 10GE SFP+ optical modules, and high-speed copper cables.
40GE QSFP+ Ports: 6 ports compatible with Módulo óptico QSFP+s and high-speed copper cables. Note: A QSFP+ optical port cannot be split into four 10GE ports.

Alimentação e Refrigeração

The S6730-S24X6Q supports dual hot-swappable power modules, allowing for AC and DC inputs:
AC Input: 100 V AC to 240 V AC, 50/60 Hz.
High-Voltage DC Input: 240 V DC.
DC Input: -48 V DC to -60 V DC.
Maximum Power Consumption: 249 W.
Typical Power Consumption: 135 W.
Fan Modules: Four pluggable fan modules with front-to-rear airflow design for efficient cooling.

Stacking and Virtualization

The switch supports stacking through its 10GE SFP+ and 40GE QSFP+ ports, allowing multiple switches to function as a single logical unit for simplified management and enhanced scalability. It also supports VXLAN L2 and L3 gateways, enabling network virtualization for flexible and efficient network designs.


Recursos de segurança

The S6730-S24X6Q offers comprehensive security features to protect network integrity:
Access Control Lists (ACLs): Permit or deny traffic based on predefined security policies.
802.1X Authentication: Ensures that only authorized users can access the network.
DHCP Snooping: Prevents unauthorized DHCP servers from distributing IP addresses.
IP Source Guard: Blocks packets with spoofed IP addresses.
Dynamic ARP Inspection (DAI): Protects against ARP spoofing attacks.

Quality of Service (QoS)

The switch provides advanced QoS features to ensure optimal performance for critical applications:
Traffic Classification: Identifies and classifies incoming traffic based on various parameters.
Traffic Policing and Shaping: Controls the rate of traffic sent or received on a network interface.
Priority Queuing: Ensures that high-priority traffic is transmitted first.
Congestion Management: Implements mechanisms to prevent and manage network congestion.

Gestão e Manutenção

The S6730-S24X6Q supports various management methods for ease of use:
Command-Line Interface (CLI): Provides a text-based interface for configuration and monitoring.
Web-Based Management: Desligadoers a graphical user interface accessible through web browsers.


Huawei CloudEngine S6730-S24X6Q Switches

Huawei All Série Switches New and Used

For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com  (Email: [email protected])



S6730-S24X6Q (02353AJW/02353AJW-001/02353AJW-003/02353AJW-004)

Version Mapping

Table 4-227 lists the mapping between the S6730-S24X6Q chassis and software versions.

Table 4-227 Version mapping

Series

Modelo

Versão do software

S6730-S

S6730-S24X6Q

02353AJW: V200R019C00 and later versions

02353AJW-001: V200R020C10 and later versions

02353AJW-003: V200R021C10SPC500 and later versions (If V200R021C00SPC100 is used, install V200R021SPH011 or a later patch.)

02353AJW-004: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.)

NOTA:

V200R021C01 is not supported.

Some models cannot be downgraded due to component upgrade. Therefore, you are advised to run the display system-software information command (supported in V200R021C00 and later versions) to check the software versions supported by the device before performing a downgrade.

Appearance and Structure

Figure 4-94 S6730-S24X6Q appearance

1

Vinte e quatro portas 10GE SFP+

Módulos e cabos aplicáveis:
  • GE optical module

  • Módulo óptico GE-CWDM

  • Módulo óptico GE-DWDM

  • Módulo de cobre GE

  • Módulo óptico 10GE SFP+ (OSXD22N00 não suportado)

  • 10GE SFP+ Copper Modules (supported in V200R023C10 and later versions)

  • Módulo óptico 10GE-CWDM

  • Módulo óptico 10GE-DWDM

  • Cabos de cobre de alta velocidade SFP+ de 1 m, 3 m, 5 m e 10 m

  • Cabos SFP+ AOC de 3 m e 10 m

  • Cabos de pilha dedicada SFP+ de 0,5 m e 1,5 m (suportados pelas últimas 16 portas SFP+ e usados apenas para empilhamento de configuração zero)

2

Seis portas ópticas QSFP+ 40GE

Módulos e cabos aplicáveis:
  • QSFP+ optical module

  • Cabos de cobre de alta velocidade QSFP+ a QSFP+ de 1 m, 3 m e 5 m

  • Cabo QSFP+ para QSFP+ AOC de 10 m

  • Cabo de pilha dedicada QSFP28 de 2 m (suportado na V200R020C10 e versões posteriores)

  • QSFP28 optical module (supported in V200R024C00 and later versions, need a license loaded)

  • 1 m QSFP28 to QSFP28 high-speed copper cable (supported in V200R024C00 and later versions, need a license loaded)

  • 10 m QSFP28 to QSFP28 AOC cable (supported in V200R024C00 and later versions, need a license loaded)

NOTA:

A QSFP+ optical port cannot be split into four 10GE ports.

In V200R024C00 and later versions, a RTU license can be loaded to increase the port rate to 100 Gbit/s.

The QSFP+ ports can work as 100GE ports after you activate the license, run the assign port-type 100ge [ ranhura slot-id | all ] command, and restart the switch.

3

Parafuso terra

NOTA:
It is used with a ground cable.

4

Slot para cartão SSD

NOTA:

This slot is reserved for future use.

5

Uma porta de console

6

Uma porta de gerenciamento ETH

7

Uma porta USB

8

Um botão PNP

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

9

Slot do módulo do ventilador 1

NOTA:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

10

Slot do módulo do ventilador 2

NOTA:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

11

Slot do módulo do ventilador 3

NOTA:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

12

Slot do módulo do ventilador 4

NOTA:

Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust))

13

Slot do módulo de alimentação 1

NOTA:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

14

Slot do módulo de alimentação 2

NOTA:

Applicable power module:

  • PAC600S12-CB (600 W AC&240 V DC Power Module)

  • PAC600S12-EB (600 W AC&240 V DC Power Module)

  • PAC600S12-DB (600 W AC&240 V DC Power Module) (applicable in V200R020C10 and later versions)

  • PDC1000S12-DB (1000 W DC Power Module)

Port Descrição

10GE SFP+ optical port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 4-228 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 4-228 Attributes of a 10GE SFP+ port

Attribute

Descrição

Tipo de conector

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Modo de trabalho

GE/10GE auto-sensing

40GE QSFP+ optical port

A 40GE QSFP+ optical port sends and receives service traffic at 40 Gbit/s. Table 4-229 describes the attributes of a QSFP+ optical port.
Table 4-229 Attributes of a QSFP+ optical port

Attribute

Descrição

Tipo de conector

MPO/LC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ba

Porta do console

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-230.
Table 4-230 Attributes of a console port

Attribute

Descrição

Tipo de conector

RJ45

Standards compliance

RS-232

Modo de trabalho

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

Porto de gerenciamento ETH

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 4-231 describes the attributes of an ETH management port.
Table 4-231 Attributes of an ETH management port

Attribute

Descrição

Tipo de conector

RJ45

Standards compliance

IEEE802.3

Working Mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 metros

In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the Configuration Guide - Basic Configuration.

Porta USB

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Indicador Descrição

Figure 4-95 Indicators on the S6730-S24X6Q
Table 4-232 Description of indicators on the switch

Não.

Indicator

Nome

Cor

Estado

Description

1

.SYS

Indicador de status do sistema

-

Desligado

O sistema não está em execução.

Verde

Piscar rápido

O sistema está sendo iniciado.

Verde

Firme em

Durante a fase de preparação da inicialização do sistema, o indicador SYS fica verde constante, o que dura no máximo 30 segundos.

Verde

Piscar lentamente

O sistema está funcionando normalmente.

Vermelho

Firme em

O sistema não funciona normalmente após o registro, ou um alarme de ventilador ou um alarme de temperatura foi gerado.

2

MST

Indicador de pilha

-

Desligado

O switch não é o switch mestre em uma pilha.

Verde

Piscando

O switch é o switch mestre em uma pilha ou um switch autônomo.

3

ID

Indicador de identificação

-

Desligado

O indicador ID não é usado (estado padrão).

Azul

Firme em

O indicador identifica o switch a ser mantido. O indicador de identificação pode ser ativado ou desativado remotamente para ajudar os engenheiros de campo a encontrar o comutador a ser mantido.

4

-

Service port indicator (10GE optical port)

NOTA:

Cada porta óptica tem dois indicadores de cor única. O da esquerda é o indicador ACT (amarelo) e o da direita é o indicador LINK (verde).

As pontas de seta mostram as posições das portas. Uma ponta de seta para baixo indica uma porta na parte inferior e uma ponta de seta para cima indica uma porta na parte superior.

-

Desligado

A porta não está conectada ou foi desligada.

Verde

Firme em

Foi estabelecida uma ligação no porto.

-

Desligado

A porta não está enviando ou recebendo dados.

Amarelo

Piscando

A porta está enviando ou recebendo dados.

5

-

Service port indicator (40GE optical port)

NOTA:

Each optical port has one single-color indicator. Arrowheads show the positions of ports.

-

Desligado

A porta não está conectada ou foi desligada.

Verde

Firme em

Foi estabelecida uma ligação no porto.

Piscando

A porta está enviando ou recebendo dados.

6

L/A

Indicador de porta ETH

-

Off

A porta ETH não está conectada.

Verde

Firme em

A porta ETH está conectada.

Verde

Piscando

A porta Eth está enviando ou recebendo dados.

7

USB

Indicador de implantação baseado em USB

-

Off

  • Nenhuma unidade flash USB está conectada ao switch.

  • A porta USB está danificada.

  • O indicador está danificado.

  • A unidade flash USB não tem nenhum arquivo de configuração e não pode ser usada para implantação.

  • O switch foi atualizado usando a unidade flash USB e está sendo reiniciado.

Verde

Firme em

Uma implantação baseada em USB foi concluída.

Verde

Piscando

O sistema está lendo dados de uma unidade flash USB.

Amarelo

Firme em

A opção copiou todos os arquivos necessários e concluiu a verificação de arquivos. A unidade flash USB pode ser removida do switch.

Vermelho

Piscando

Ocorreu um erro quando o sistema está executando o arquivo de configuração ou lendo dados da unidade flash USB.

Power Supply Configuration

Há88pl99ace1switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Dissipação de calor

Há88pl99ace1S6730-S24X6Q uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.

This figure only shows the airflow direction and does not depict the actual device.

Especificações Técnicas

Table 4-233 lists technical specifications of the S6730-S24X6Q.

Table 4-233 Technical specifications

Item

Description

Memória (RAM)

4 GB

Lampejo

2 GB no total. Para ver o tamanho da memória flash disponível, execute the versão de exibição comando.

Tempo médio entre falhas (MTBF)

62,27 anos

Tempo médio de reparação (MTTR)

2 horas

Disponibilidade

> 0,99999

Proteção contra surtos na porta de serviço

N/A

Proteção contra surtos na fonte de alimentação

  • Usando módulos de alimentação CA: ±6 kV no modo diferencial, ±6 kV no modo comum

  • Usando módulos de alimentação DC: ±2 kV no modo diferencial, ±4 kV no modo comum

Dimensions (H x W x D)

  • Dimensões básicas (excluindo as peças salientes do corpo): 43,6 mm x 442,0 mm x 420,0 mm (1,72 pol. x 17,4 pol. x 16,5 pol.)

  • Dimensões máximas (a profundidade é a distância das portas no painel frontal até a alça no painel traseiro): 43,6 mm x 442,0 mm x 446,0 mm (1,72 pol. x 17,4 pol. x 17,6 pol.)

Weight (with packaging)

8.9 kg (19.62 lb)

Portas de empilhamento

  • Qualquer porta SFP+ 10GE (um máximo de 16 portas físicas)

  • Qualquer porta QSFP+ 40GE (um máximo de 6 portas físicas)

RTC

Suportado

RPS

Não suportado

Poe

Não suportado

Faixa de tensão nominal

  • Entrada AC: 100 V AC a 240 V AC, 50/60 Hz

  • Entrada de alta tensão DC: 240 V DC

  • Entrada DC: -48 V DC a -60 V DC

Faixa de tensão máxima

  • Entrada AC: 90 V AC a 290 V AC, 45 Hz a 65 Hz

  • Entrada de alta tensão DC: 190 V DC a 290 V DC

  • Entrada DC: -38,4 V DC a -72 V DC

Consumo máximo de energia

High temperature 45°C (113°F), 100% traffic, and dual power modules: 170 W

High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 249 W

Consumo de energia típico

30% traffic under the ATIS standard and dual power modules: 135 W

Temperatura de funcionamento

-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTA:

Quando a altitude é de 1800-5000 m (5906-16404 pés), a temperatura de operação mais alta reduz em 1°C (1,8°F) cada vez que a altitude aumenta em 220 m (722 pés).

O interruptor não pode ser iniciado quando a temperatura ambiente é inferior a 0°C (32°F).

Temperatura de armazenamento

-40°C a +70°C (-40°F a +158°F)

Ruído sob temperatura normal (27°C, potência sonora)

< 65 dB(A)

Humidade relativa do ar

5% to 95%, noncondensing

Altitude de operação

0-5000 m (0-16404 pés)

Certificação

  • Certificação EMC

  • Certificação de segurança

  • Certificação de fabricação

Número da peça

02353AJW

02353AJW-001

02353AJW-003

02353AJW-004


tag-icon Tags quentes : Huawei Switches

Copyright © 2014-2024 Hi-Network.com | HAILIAN TECHNOLOGY CO., LIMITED | All Rights Reserved.
Our company's operations and information are independent of the manufacturers' positions, nor a part of any listed trademarks company.