The HuaweiRE88PL99ace1S6730-S24X6Q | is a high-performance Ethernet interruptor designed to meet the demands of modern data centers and campus networks. It offers advanced features and robust specifications to ensure efficient and reliable network operations.
▪ High Port Density: 24 x 10 Gigabit SFP+ ports and 6 x 40 Gigabit QSFP+ ports.
▪ High Switching Capacity: Up to 2.4 Tbit/s to handle heavy traffic loads.
▪ Advanced Layer 2 and Layer 3 Features: Supports comprehensive protocols for versatile network configurations.
▪ Stacking Capability: Supports stacking through 10GE SFP+ and 40GE QSFP+ ports for simplified management.
▪ Energy Efficiency: Designed for low power consumption to reduce operational costs.
▪ Comprehensive Security: Desligadoers features like ACLs, 802.1X authentication, and DHCP snooping for enhanced network protection.
▪ Qualidade de Serviço (QoS): Provides traffic classification and prioritization to ensure optimal performance for critical applications.
▪ Flexible Management: Supports various management methods, including CLI, web-based management, and SNMP.
▪ High Reliability: Features redundant power supplies and hot-swappable fan modules for continuous operation.
▪ Virtual Extensible LAN (VXLAN): Supports VXLAN L2 and L3 gateways for network virtualization.
Ports: 24 x 10GE SFP+ ports, 6 x 40GE QSFP+ ports.
Switching Capacity: 2.4 Tbit/s.
Forwarding Performance: 480 Mpps.
Dimensões (A x L x P): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.).
Peso (com embalagem): 8,9 kg (19,62 lb).
Power Supply: Supports dual AC and DC power modules.
Operating Temperature: -5°C a +45°C (23°F a 113°F) a uma altitude de 0-1800 m (0-5906 pés).
Operating Humidity: 5% a 95%, sem condensação.
Stacking Support: Up to 16 physical ports for stacking using 10GE SFP+ and 40GE QSFP+ ports.
Airflow Direction: Air intake from front, air exhaustion from rear (front-to-rear).
10GE SFP+ Ports: 24 ports supporting various optical modules and cables, including Módulo óptico GEs, 10GE SFP+ optical modules, and high-speed copper cables.
40GE QSFP+ Ports: 6 ports compatible with Módulo óptico QSFP+s and high-speed copper cables. Note: A QSFP+ optical port cannot be split into four 10GE ports.
The S6730-S24X6Q supports dual hot-swappable power modules, allowing for AC and DC inputs:
AC Input: 100 V AC to 240 V AC, 50/60 Hz.
High-Voltage DC Input: 240 V DC.
DC Input: -48 V DC to -60 V DC.
Maximum Power Consumption: 249 W.
Typical Power Consumption: 135 W.
Fan Modules: Four pluggable fan modules with front-to-rear airflow design for efficient cooling.
The switch supports stacking through its 10GE SFP+ and 40GE QSFP+ ports, allowing multiple switches to function as a single logical unit for simplified management and enhanced scalability. It also supports VXLAN L2 and L3 gateways, enabling network virtualization for flexible and efficient network designs.
The S6730-S24X6Q offers comprehensive security features to protect network integrity:
Access Control Lists (ACLs): Permit or deny traffic based on predefined security policies.
802.1X Authentication: Ensures that only authorized users can access the network.
DHCP Snooping: Prevents unauthorized DHCP servers from distributing IP addresses.
IP Source Guard: Blocks packets with spoofed IP addresses.
Dynamic ARP Inspection (DAI): Protects against ARP spoofing attacks.
The switch provides advanced QoS features to ensure optimal performance for critical applications:
Traffic Classification: Identifies and classifies incoming traffic based on various parameters.
Traffic Policing and Shaping: Controls the rate of traffic sent or received on a network interface.
Priority Queuing: Ensures that high-priority traffic is transmitted first.
Congestion Management: Implements mechanisms to prevent and manage network congestion.
The S6730-S24X6Q supports various management methods for ease of use:
Command-Line Interface (CLI): Provides a text-based interface for configuration and monitoring.
Web-Based Management: Desligadoers a graphical user interface accessible through web browsers.
Huawei CloudEngine S6730-S24X6Q Switches
Huawei All Série Switches New and Used
For Cisco product list and quote, please visit: https://www.hi-network.com/categories/cisco or contact us at www.hi-network.com (Email: [email protected])
Table 4-227 lists the mapping between the S6730-S24X6Q chassis and software versions.
Series | Modelo | Versão do software |
---|---|---|
S6730-S | S6730-S24X6Q | 02353AJW: V200R019C00 and later versions 02353AJW-001: V200R020C10 and later versions 02353AJW-003: V200R021C10SPC500 and later versions (If V200R021C00SPC100 is used, install V200R021SPH011 or a later patch.) 02353AJW-004: V200R021C10SPC600 and later versions (If V200R021C00SPC100 is used, install V200R021SPH013 or a later patch.) NOTA: V200R021C01 is not supported. Some models cannot be downgraded due to component upgrade. Therefore, you are advised to run the display system-software information command (supported in V200R021C00 and later versions) to check the software versions supported by the device before performing a downgrade. |
1 | Vinte e quatro portas 10GE SFP+ Módulos e cabos aplicáveis:
| 2 | Seis portas ópticas QSFP+ 40GE Módulos e cabos aplicáveis:
NOTA: A QSFP+ optical port cannot be split into four 10GE ports. In V200R024C00 and later versions, a RTU license can be loaded to increase the port rate to 100 Gbit/s. The QSFP+ ports can work as 100GE ports after you activate the license, run the assign port-type 100ge [ ranhura slot-id | all ] command, and restart the switch. |
3 | Parafuso terra NOTA: It is used with a ground cable. | 4 | Slot para cartão SSD NOTA: This slot is reserved for future use. |
5 | Uma porta de console | 6 | Uma porta de gerenciamento ETH |
7 | Uma porta USB | 8 | Um botão PNP NOTICE: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
9 | Slot do módulo do ventilador 1 NOTA: Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 10 | Slot do módulo do ventilador 2 NOTA: Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
11 | Slot do módulo do ventilador 3 NOTA: Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) | 12 | Slot do módulo do ventilador 4 NOTA: Applicable fan module: FAN-031A-B (Fan Box (B, Fan Panel Side Exhaust)) |
13 | Slot do módulo de alimentação 1 NOTA: Applicable power module:
| 14 | Slot do módulo de alimentação 2 NOTA: Applicable power module:
|
10GE SFP+ optical port
40GE QSFP+ optical port
Porta do console
Porto de gerenciamento ETH
Attribute | Descrição |
---|---|
Tipo de conector | RJ45 |
Standards compliance | IEEE802.3 |
Working Mode | 10/100 Mbit/s auto-sensing |
Maximum transmission distance | 100 metros |
Porta USB
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Não. | Indicator | Nome | Cor | Estado | Description |
---|---|---|---|---|---|
1 | .SYS | Indicador de status do sistema | - | Desligado | O sistema não está em execução. |
Verde | Piscar rápido | O sistema está sendo iniciado. | |||
Verde | Firme em | Durante a fase de preparação da inicialização do sistema, o indicador SYS fica verde constante, o que dura no máximo 30 segundos. | |||
Verde | Piscar lentamente | O sistema está funcionando normalmente. | |||
Vermelho | Firme em | O sistema não funciona normalmente após o registro, ou um alarme de ventilador ou um alarme de temperatura foi gerado. | |||
2 | MST | Indicador de pilha | - | Desligado | O switch não é o switch mestre em uma pilha. |
Verde | Piscando | O switch é o switch mestre em uma pilha ou um switch autônomo. | |||
3 | ID | Indicador de identificação | - | Desligado | O indicador ID não é usado (estado padrão). |
Azul | Firme em | O indicador identifica o switch a ser mantido. O indicador de identificação pode ser ativado ou desativado remotamente para ajudar os engenheiros de campo a encontrar o comutador a ser mantido. | |||
4 | - | Service port indicator (10GE optical port) NOTA: Cada porta óptica tem dois indicadores de cor única. O da esquerda é o indicador ACT (amarelo) e o da direita é o indicador LINK (verde). As pontas de seta mostram as posições das portas. Uma ponta de seta para baixo indica uma porta na parte inferior e uma ponta de seta para cima indica uma porta na parte superior. | - | Desligado | A porta não está conectada ou foi desligada. |
Verde | Firme em | Foi estabelecida uma ligação no porto. | |||
- | Desligado | A porta não está enviando ou recebendo dados. | |||
Amarelo | Piscando | A porta está enviando ou recebendo dados. | |||
5 | - | Service port indicator (40GE optical port) NOTA: Each optical port has one single-color indicator. Arrowheads show the positions of ports. | - | Desligado | A porta não está conectada ou foi desligada. |
Verde | Firme em | Foi estabelecida uma ligação no porto. | |||
Piscando | A porta está enviando ou recebendo dados. | ||||
6 | L/A | Indicador de porta ETH | - | Off | A porta ETH não está conectada. |
Verde | Firme em | A porta ETH está conectada. | |||
Verde | Piscando | A porta Eth está enviando ou recebendo dados. | |||
7 | USB | Indicador de implantação baseado em USB | - | Off |
|
Verde | Firme em | Uma implantação baseada em USB foi concluída. | |||
Verde | Piscando | O sistema está lendo dados de uma unidade flash USB. | |||
Amarelo | Firme em | A opção copiou todos os arquivos necessários e concluiu a verificação de arquivos. A unidade flash USB pode ser removida do switch. | |||
Vermelho | Piscando | Ocorreu um erro quando o sistema está executando o arquivo de configuração ou lendo dados da unidade flash USB. |
Há88pl99ace1switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Há88pl99ace1S6730-S24X6Q uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Table 4-233 lists technical specifications of the S6730-S24X6Q.
Item | Description |
---|---|
Memória (RAM) | 4 GB |
Lampejo | 2 GB no total. Para ver o tamanho da memória flash disponível, execute the versão de exibição comando. |
Tempo médio entre falhas (MTBF) | 62,27 anos |
Tempo médio de reparação (MTTR) | 2 horas |
Disponibilidade | > 0,99999 |
Proteção contra surtos na porta de serviço | N/A |
Proteção contra surtos na fonte de alimentação |
|
Dimensions (H x W x D) |
|
Weight (with packaging) | 8.9 kg (19.62 lb) |
Portas de empilhamento |
|
RTC | Suportado |
RPS | Não suportado |
Poe | Não suportado |
Faixa de tensão nominal |
|
Faixa de tensão máxima |
|
Consumo máximo de energia | High temperature 45°C (113°F), 100% traffic, and dual power modules: 170 W High temperature 45°C (113°F), 100% traffic, long-distance optical module, 100% fan speed, and dual power modules: 249 W |
Consumo de energia típico | 30% traffic under the ATIS standard and dual power modules: 135 W |
Temperatura de funcionamento | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTA: Quando a altitude é de 1800-5000 m (5906-16404 pés), a temperatura de operação mais alta reduz em 1°C (1,8°F) cada vez que a altitude aumenta em 220 m (722 pés). O interruptor não pode ser iniciado quando a temperatura ambiente é inferior a 0°C (32°F). |
Temperatura de armazenamento | -40°C a +70°C (-40°F a +158°F) |
Ruído sob temperatura normal (27°C, potência sonora) | < 65 dB(A) |
Humidade relativa do ar | 5% to 95%, noncondensing |
Altitude de operação | 0-5000 m (0-16404 pés) |
Certificação |
|
Número da peça | 02353AJW 02353AJW-001 02353AJW-003 02353AJW-004 |